{
  "schemaVersion": 1,
  "kind": "workbook",
  "key": "epa-simplified-ghg/2026",
  "title": "EPA Simplified GHG Emissions Calculator",
  "summary": "Calculate annual Scope 1, location- and market-based Scope 2, and selected Scope 3 emissions using the pinned EPA source workbook with traceable fuel, eGRID and GWP factors.",
  "edition": "2026",
  "html": "https://formualizer.com/catalog/epa-simplified-ghg",
  "parent": {
    "text": "https://formualizer.com/catalog/subjects/energy/llms.txt",
    "json": "https://formualizer.com/catalog/subjects/energy/llms.json"
  },
  "publisher": "U.S. Environmental Protection Agency (EPA — Center for Corporate Climate Leadership)",
  "publisherPageUrl": "https://www.epa.gov/climateleadership/simplified-ghg-emissions-calculator",
  "verificationLevel": "scenario-independent-arithmetic",
  "verificationExplanation": "Changed-input scenarios match an independent calculation.",
  "rightsExplanation": "The bundle classifies this government source as public domain.",
  "limitations": [
    "2026 is a catalog edition label, not a claim of EPA 2026 emission factors. Source contains March 2024 factor citations and historical data; latest EPA release not established.",
    "Worked example rows are deliberately excluded by publisher SUM ranges. Mapped source rows start after examples; omitted active rows produce the source zero baseline.",
    "Scope 3 is limited to the four categories supported by this simplified workbook; not a complete GHG Protocol corporate value-chain inventory.",
    "Native XLOOKUP works in the pinned WASM runtime; no table hydration or JS UDF calculation callback is required.",
    "Gross location- and market-based totals are alternative reporting views; never add them together. Offsets affect net outputs only.",
    "Execution uses a deterministic macro/ActiveX-free xlsx derivative. All worksheet cells, formulas, factor data and workbook defined names are unchanged; the publisher's original file is pinned separately. Catalog hook adds native aggregate formulas in previously empty Summary cells.",
    "Fuel/unit, model-year and waste/disposal compatibility must follow the workbook. Use the publisher's waste and disposal compatibility rules and supporting assumptions.",
    "The runtime adds four native SUM formulas in unused Summary cells; all publisher source formulas and lookup datasets are evaluated natively."
  ],
  "releaseBlockers": [],
  "licenseClass": "public-domain-gov",
  "disclaimer": "Catalog calculations, not certification.",
  "removal": "Entries are removed on the publisher’s request.",
  "flows": [
    {
      "id": "quick_scope_1_2_3_footprint",
      "title": "Quick Scope 1, 2 and 3 footprint",
      "description": "13 inputs for one stationary source, one owned fleet group, one electricity site, business vehicle travel and commuting. Annual therms/gallons/kWh/vehicle-miles; outputs metric tons CO2e. Provide each activity with all companion selectors; omitted active rows remain blank. Scope 3 covers selected categories only.",
      "inputPorts": [
        "stationary_fuel",
        "stationary_quantity",
        "stationary_unit",
        "mobile_vehicle_type",
        "mobile_model_year",
        "mobile_fuel_gallons",
        "mobile_vehicle_miles",
        "electricity_subregion",
        "electricity_kwh",
        "business_vehicle_type",
        "business_vehicle_miles",
        "commuting_vehicle_type",
        "commuting_vehicle_miles"
      ],
      "outputPorts": [
        "scope_1_gross",
        "scope_2_location_gross",
        "scope_2_market_gross",
        "scope_3_gross",
        "organization_location_gross",
        "organization_market_gross"
      ]
    },
    {
      "id": "full_epa_ghg_inventory",
      "title": "Full EPA GHG inventory",
      "description": "Complete active source schedules as partial records keyed by Excel row, plus quick scalars. Includes stationary/mobile, refrigeration, fire, purchased gases, electricity/steam, business travel, commuting, upstream transportation, waste and offsets. Do not populate a quick scalar and record field targeting the same cell. Use one method per fugitive source. All outputs metric tons CO2e.",
      "inputPorts": [
        "stationary_fuel",
        "stationary_quantity",
        "stationary_unit",
        "mobile_vehicle_type",
        "mobile_model_year",
        "mobile_fuel_gallons",
        "mobile_vehicle_miles",
        "electricity_subregion",
        "electricity_kwh",
        "business_vehicle_type",
        "business_vehicle_miles",
        "commuting_vehicle_type",
        "commuting_vehicle_miles",
        "stationary_sources",
        "mobile_sources",
        "biodiesel_percent",
        "ethanol_percent",
        "electricity_sources",
        "steam_sources",
        "refrigeration_material_balance",
        "fire_material_balance",
        "refrigeration_simplified_balance",
        "fire_simplified_balance",
        "refrigeration_screening",
        "fire_screening",
        "purchased_gases",
        "business_vehicles",
        "business_public_transport",
        "business_air",
        "commuting_vehicles",
        "commuting_public_transport",
        "upstream_vehicle_transport",
        "upstream_ton_mile_transport",
        "waste_sources",
        "purchased_offsets"
      ],
      "outputPorts": [
        "scope_1_gross",
        "scope_2_location_gross",
        "scope_2_market_gross",
        "scope_3_gross",
        "organization_location_gross",
        "organization_market_gross",
        "stationary_combustion",
        "mobile_sources_emissions",
        "refrigeration_ac",
        "fire_suppression",
        "purchased_gases_emissions",
        "purchased_electricity_location",
        "purchased_steam_location",
        "purchased_electricity_market",
        "purchased_steam_market",
        "scope_1_net",
        "scope_2_location_net",
        "scope_2_market_net",
        "business_travel",
        "employee_commuting",
        "upstream_transport",
        "waste",
        "stationary_biomass_co2",
        "mobile_biomass_co2",
        "organization_location_net"
      ]
    }
  ],
  "example": {
    "id": "scope_1_stationary_and_mobile",
    "flow": "quick_scope_1_2_3_footprint",
    "inputs": {
      "stationary_fuel": "Natural Gas",
      "stationary_quantity": 10000,
      "stationary_unit": "Therm",
      "mobile_vehicle_type": "Passenger Cars - Gasoline",
      "mobile_model_year": 2019,
      "mobile_fuel_gallons": 500,
      "mobile_vehicle_miles": 12400
    },
    "expectedOutputs": {
      "scope_1_gross": 57.51091017817046,
      "scope_2_location_gross": 0,
      "scope_2_market_gross": 0,
      "scope_3_gross": 0,
      "organization_location_gross": 57.51091017817046,
      "organization_market_gross": 57.51091017817046
    },
    "inputsJson": "{\"stationary_fuel\":\"Natural Gas\",\"stationary_quantity\":10000,\"stationary_unit\":\"Therm\",\"mobile_vehicle_type\":\"Passenger Cars - Gasoline\",\"mobile_model_year\":2019,\"mobile_fuel_gallons\":500,\"mobile_vehicle_miles\":12400}",
    "expectedOutputsJson": "{\"scope_1_gross\":57.51091017817046,\"scope_2_location_gross\":0,\"scope_2_market_gross\":0,\"scope_3_gross\":0,\"organization_location_gross\":57.51091017817046,\"organization_market_gross\":57.51091017817046}"
  },
  "ports": {
    "text": "https://formualizer.com/catalog/agents/epa-simplified-ghg/2026/ports/llms.txt",
    "json": "https://formualizer.com/catalog/agents/epa-simplified-ghg/2026/ports/llms.json"
  },
  "service": {
    "openapi": "https://catalog.formualizer.com/v1/models/epa-simplified-ghg/2026/openapi.json",
    "types": "https://catalog.formualizer.com/v1/models/epa-simplified-ghg/2026/types.d.ts",
    "fio": "https://catalog.formualizer.com/v1/models/epa-simplified-ghg/2026/fio.yaml",
    "evaluate": "https://catalog.formualizer.com/v1/models/epa-simplified-ghg/2026/evaluate",
    "mcp": "https://catalog.formualizer.com/v1/mcp"
  }
}
