# MIT BuildVac Ventilation Requirements Site-served catalog guide. Service API contracts remain at catalog.formualizer.com. - [Workbook page](https://formualizer.com/catalog/mit-buildvac-ventilation) - [Subject guide (text)](https://formualizer.com/catalog/subjects/engineering/llms.txt) - [Subject guide (JSON)](https://formualizer.com/catalog/subjects/engineering/llms.json) - [Publisher page](https://netzerobuildings.mit.edu/ventilation-requirements) - [Ports (text)](https://formualizer.com/catalog/agents/mit-buildvac-ventilation/v1.0/ports/llms.txt) - [Ports (JSON)](https://formualizer.com/catalog/agents/mit-buildvac-ventilation/v1.0/ports/llms.json) - [OpenAPI](https://catalog.formualizer.com/v1/models/mit-buildvac-ventilation/v1.0/openapi.json) - [TypeScript types](https://catalog.formualizer.com/v1/models/mit-buildvac-ventilation/v1.0/types.d.ts) - [SheetPort manifest](https://catalog.formualizer.com/v1/models/mit-buildvac-ventilation/v1.0/fio.yaml) - [Evaluate endpoint (POST)](https://catalog.formualizer.com/v1/models/mit-buildvac-ventilation/v1.0/evaluate) - [MCP endpoint (POST)](https://catalog.formualizer.com/v1/mcp) ```json { "schemaVersion": 1, "kind": "workbook", "key": "mit-buildvac-ventilation/v1.0", "title": "MIT BuildVac Ventilation Requirements", "summary": "MIT BuildVac Ventilation Requirements with version-pinned publisher workbook calculations, scenario inputs and formula-level audit traces.", "edition": "v1.0", "html": "https://formualizer.com/catalog/mit-buildvac-ventilation", "parent": { "text": "https://formualizer.com/catalog/subjects/engineering/llms.txt", "json": "https://formualizer.com/catalog/subjects/engineering/llms.json" }, "publisher": "MIT Sustainable Design Lab", "publisherPageUrl": "https://netzerobuildings.mit.edu/ventilation-requirements", "verificationLevel": "scenario-independent-arithmetic", "verificationExplanation": "Changed-input scenarios match an independent calculation.", "rightsExplanation": "This is an academic source; this catalog class does not establish a redistribution licence.", "limitations": [ "Edition v1.0 is a catalog pin, not a separately established publisher release number.", "Heating uses the same cold supply temperature as cooling exactly as authored; this conceptual comparison is not full HVAC design.", "Runtime approximate VLOOKUP fails exact source default on unsorted Lists!A1:D18. Exact-match adaptation is bounded to documented program enum; source bytes are unchanged." ], "releaseBlockers": [], "licenseClass": "open-academic", "disclaimer": "Catalog calculations, not certification.", "removal": "Entries are removed on the publisher’s request.", "flows": [ { "id": "quick_ventilation_shafts", "title": "Quick ventilation and shaft comparison", "description": "Compare DOAS and all-air shafts with coupled density/rate method switches. Supply all custom numeric ports when activating their methods. Baseline supply temperature 12.8°C and air properties remain pinned.", "inputPorts": [ "program_area_m2", "program", "occupant_density_method", "custom_occupant_density", "flow_rate_method", "custom_flow_per_area", "custom_flow_per_person", "doas_velocity_m_per_s", "doas_safety_fraction", "peak_heating_kw", "peak_cooling_kw", "cooling_setpoint_c", "heating_setpoint_c", "all_air_velocity_m_per_s", "all_air_safety_fraction" ], "outputPorts": [ "people_count", "outdoor_flow_l_per_s", "doas_total_shaft_m2", "all_air_total_shaft_m2", "shaft_comparison" ] }, { "id": "full_ventilation_assessment", "title": "Full ventilation and all-air assessment", "description": "All source decision inputs including air properties and supply temperature, plus supply/return/exhaust diagnostics. Fixed return ratio 80%; source lookup table is pinned.", "inputPorts": [ "program_area_m2", "program", "occupant_density_method", "custom_occupant_density", "flow_rate_method", "custom_flow_per_area", "custom_flow_per_person", "doas_velocity_m_per_s", "doas_safety_fraction", "peak_heating_kw", "peak_cooling_kw", "cooling_setpoint_c", "heating_setpoint_c", "supply_air_temperature_c", "air_specific_heat", "air_density", "all_air_velocity_m_per_s", "all_air_safety_fraction" ], "outputPorts": [ "people_count", "outdoor_flow_l_per_s", "outdoor_flow_m3_per_s", "doas_supply_shaft_m2", "doas_exhaust_shaft_m2", "doas_total_shaft_m2", "heating_flow_m3_per_s", "cooling_flow_m3_per_s", "all_air_supply_shaft_m2", "all_air_return_shaft_m2", "all_air_total_shaft_m2", "shaft_comparison" ] } ], "example": { "id": "quick_ventilation_shafts_larger_office", "flow": "quick_ventilation_shafts", "inputs": { "program_area_m2": 10000 }, "expectedOutputs": { "people_count": 500, "outdoor_flow_l_per_s": 4250, "doas_total_shaft_m2": 1.2218749999999998, "all_air_total_shaft_m2": 6.995576139985888, "shaft_comparison": "Shafts for the all-air system are larger than shafts for the dedicated outdoor air system" }, "inputsJson": "{\"program_area_m2\":10000}", "expectedOutputsJson": "{\"people_count\":500,\"outdoor_flow_l_per_s\":4250,\"doas_total_shaft_m2\":1.2218749999999998,\"all_air_total_shaft_m2\":6.995576139985888,\"shaft_comparison\":\"Shafts for the all-air system are larger than shafts for the dedicated outdoor air system\"}" }, "ports": { "text": "https://formualizer.com/catalog/agents/mit-buildvac-ventilation/v1.0/ports/llms.txt", "json": "https://formualizer.com/catalog/agents/mit-buildvac-ventilation/v1.0/ports/llms.json" }, "service": { "openapi": "https://catalog.formualizer.com/v1/models/mit-buildvac-ventilation/v1.0/openapi.json", "types": "https://catalog.formualizer.com/v1/models/mit-buildvac-ventilation/v1.0/types.d.ts", "fio": "https://catalog.formualizer.com/v1/models/mit-buildvac-ventilation/v1.0/fio.yaml", "evaluate": "https://catalog.formualizer.com/v1/models/mit-buildvac-ventilation/v1.0/evaluate", "mcp": "https://catalog.formualizer.com/v1/mcp" } } ```